Photos – Defective Items

The following Images are a collection of unusual defective inspection items.

 


crushedbeam

 

Structure

This is a pair of crushed beams sitting on a column.  A shim plate would have prevented this problem.

 

 

 

 


dscn0225

 

Chimney

This appliance chimney lacks a liner.  This is a monoxide hazard in the house.

 

 

 

 

 


dscn0230

 

Electrical

Pyrolysis is occurring on sub floor above basement laundry light. This is a fire hazard!

 

 

 

 

 


pict0361

 

Electrical 

Two smaller wires are tapped in with the mains.  These wires should pass through a circuit breaker prior to distribution in the house.  This is a fire hazard. 

 

 

 

 


pict0742

 

Plumbing 

It would be difficult to run a snake through this access fitting. 

 

 

 

 

 


pict1108

 

Plumbing

This situation is asking for a backup in the sewer line.

 

 

 

 

 


pict0091

 

Heating

Presence of loose flaking Asbestos on steam piping is a health hazard.

 

 

 

 

 

 


pict0243

 

Electrical 

Lack of proper wiring makes this a shock hazard. 

 

 

 

 

 

 


pict0598b

 

Structure

Beam should rest on cement foundation in "beam pocket" with an air gap all around.

 

 

 

 

 


pict0796

 

Plumbing

This steel fitting in the copper water line will cause cathodic corrosion, which will lead to leaks.

 

 

 

 

 

 


pict0975

 

Roofing

The roof is past it's intended life.

 

 

 

 

 

 


pict1544a

 

Structure

The steel post in the basement was rusted through to the concrete core.

 

 

 

 

 

 


pict2290a

 

Heating

Nothing wrong here.  It was interesting that the home owner took time to polish the copper pipes and paint the iron pipes black.  

 

 

 

 

 


pict2370a

 

Plumbing

The leaking trap was replaced with a vacumn hose.

 

 

 

 

 

 


pipediaper

 

Plumbing

The leaking water from this trap was being caught by a diaper!